Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://tede.unifacs.br/tede/handle/tede/356
Registro completo de metadados
Campo DCValorIdioma
dc.creatorCabussú, Mário Seixaspt_BR
dc.creator.Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4746073U2por
dc.contributor.advisor1Valente, André Luiz de Carvalhopt_BR
dc.contributor.advisor1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4708747Z8por
dc.contributor.referee1Carvalho, Edgard Bacic dept_BR
dc.contributor.referee1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4793423E6por
dc.contributor.referee2Costa, Caiuby Alves dapt_BR
dc.contributor.referee2Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4797876P8por
dc.date.accessioned2016-04-29T14:18:39Z-
dc.date.available2010-03-18pt_BR
dc.date.issued2009-10-16pt_BR
dc.identifier.citationCABUSSÚ, Mário Seixas. O impacto do ambiente corrisivo na definição do custo de serviço da distribuição. 2009. 100 f. Dissertação (Mestrado em Energia) - Universidade Salvador, Salvador, 2009.por
dc.identifier.urihttp://teste.tede.unifacs.br:8080/tede/handle/tede/356-
dc.description.resumoA Resolução ANEEL 024/2000, no seu artigo 8º atribuiu 06 parâmetros para definição de conjuntos semelhantes: 1) área, 2) extensão primária, em Km², 3) a média mensal de energia consumida, em KWh, nos últimos 12 meses, 4) total de unidades consumidoras atendidas, 5) a potencia instalada em KVA e 6) se pertence ao sistema interligado. Aos conjuntos foram atribuídos metas de qualidade a serem alcançados ao longo do tempo. Em 2004 foi criada a resolução ANEEL 063 estabelecendo multa às violações dos conjuntos que não consigam alcançar os objetivos definidos. A hipótese na dissertação é que os efeitos da corrosão provocados pela poluição e salinidade causam impactos significativos nos custos dos serviços e que a utilização de novos materiais e equipamentos melhora os índices de qualidade, com um custo mais baixo que o padrão convencional. São mostrados os diversos padrões utilizados para construção de rede da Coelba utilizados na região Metropolitana de Salvador e Porto de Sauípe devido aos efeitos da corrosão salina e industrial, de maneira a garantir os indicadores de qualidade definidos pela ANEEL. Foi montado um experimento na subestação de Paripe, localizada a 2 km da orla marítima, na Baía de Aratu, na região Metropolitana de Salvador, com uma estação metereológica, coletores de cloreto, um amostrador de partículas portátil e um sistema de captura de corrente de fuga em diversos isoladores de 15 kV, bem como, retirados materiais de campo da região para analise em laboratório, com o objetivo de avaliar o grau de corrosividade da região. Na Coelba existem 05 conjuntos com as mesmas características, sendo feitas comparações relativas aos diversos padrões adotados devido ao grau de agressividade com custos operacionais diferentes. Este estudo concluiu que teremos de adotar padrões de rede de distribuição de energia elétrica diferenciados, nos locais com elevada corrosão, a fim de garantir um custo do serviço elétrico mais adequado para a sociedade. O monitoramento das regiões com corrosão acentuada é imperativo para que se possa avaliar os materiais e seu desempenho ao longo do tempo, bem como passamos a adotar medidas mitigadoras para baixar o custo da manutenção e aumentar a disponibilidade da energia elétrica. Existem definições municipais ou federais que interferem diretamente nos padrões de rede e nos custos de manutenção e operação, como exemplo as áreas com patrimônio tombado e de preservação ambiental.por
dc.description.abstractANEEL Resolution 024/2000, in its Article 8 gave 06 parameters for defining sets: 1) area, 2) primary extension, in square km, 3) the average monthly energy consumption in kWh over the past 12 months, 4) total consumer units served, , 5) the generating capacity in KVA and 6) belongs to the interconnected system. To the sets were assigned quality goals to be achieved over time. In 2004 was created ANEEL Resolution 063 establishing fines for the sets that fail to achieve the defined objectives. The hypothesis of this dissertation is that the effects of corrosion caused by pollution and salinity cause significant impacts on services costs and that the use of new materials and equipment improves the quality indexes with a lower cost than the conventional ones. The different standards used for network construction which Coelba uses in the metropolitan area of Salvador and Porto de Sauipe due to the effects of salt and industrial corrosion, so as to ensure the quality indicators defined by ANEEL are shown. An experiment was set at Paripe substation, located 2 km away from the seafront, on Aratu Bay, in the metropolitan area of Salvador, with a meteorological station, chloride collectors, a portable particle sampler and a leaking current capture system on many 15 kV insulators, as well as material taken from the field for laboratorial analysis, with the aim of evaluating the degree of corrosiveness of the region. In Coelba there are 05 sets with the same characteristics, being made relative comparisons between the adopted standards due aggressiveness degree and different operating costs. This study concludes that we have to adopt standards for differential electric power distribution in places with increased corrosion levels, to ensure a more appropriate cost of electric service for society. The monitoring of regions with high corrosion is imperative so that we can assess the materials and their performance over time, As we adopted mitigation measures to reduce the maintenance cost and increase the availability of electric power. There are municipal or federal definitions that directly affect the power network standards and the costs of maintenance and operation, as an example, the areas of heritage buildings and environmental preservation.eng
dc.description.provenanceMade available in DSpace on 2016-04-29T14:18:39Z (GMT). No. of bitstreams: 1 Dissertacao Mario Seixas Cabussu 2009 completo.pdf: 2527243 bytes, checksum: 373ea983536b4e6d410221c3c6ab780e (MD5) Previous issue date: 2009-10-16eng
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superiorpt_BR
dc.formatapplication/pdfpor
dc.languageporpor
dc.publisherUniversidade Salvadorpor
dc.publisher.departmentEnergiapor
dc.publisher.countryBRpor
dc.publisher.initialsUNIFACSpor
dc.publisher.programPrograma de Pós-Graduação em Regulação da Indústria de Energiapor
dc.rightsAcesso Abertopor
dc.subjectCorrosãopor
dc.subjectSalinidadepor
dc.subjectPoluição Industrialpor
dc.subjectCorrosioneng
dc.subjectSalinityeng
dc.subjectIndustrial Pollutioneng
dc.subject.cnpqCNPQ::ENGENHARIAS::ENGENHARIA ELETRICApor
dc.titleO impacto do ambiente corrisivo na definição do custo de serviço da distribuiçãopor
dc.typeDissertaçãopor
Aparece nas coleções:Regulação da Industria de Energia

Arquivos associados a este item:
Arquivo TamanhoFormato 
Dissertacao Mario Seixas Cabussu 2009 completo.pdf2,47 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.